氣體增壓泵故障及其處理方法
氣體增壓泵故障及其處理方法1泵不工作:
1 pump does not work:
a.檢查驅動氣源是否開啟,驅動壓力是否滿足要求;
A. check the drive source is turned on, the driving pressure whether meet the requirements;
正常空氣增壓泵的進氣壓力要求3-8bar,泵長期不工作,應先向驅動氣口內噴少量潤滑油,最好為硅油,然后驅動氣壓盡量調高,待泵正常運行幾分鐘后,再裝氣壓調至所需壓力,新泵裝配過程中,都會在換向閥內涂一層潤滑脂,長期不用時,潤滑脂會凝固。
The normal air intake pressure booster pump for 3-8bar, the pump does not work, should first to drive air outlet in spray a small amount of lubricating oil, preferably silicone oil, then driven pressure to increase, to pump the normal operation after a few minutes, and then loaded pressure adjusted to the required pressure, the new pump assembly process, will be in the reversing valve coated with a layer of grease, not a long time, will be solidified lubricating grease.
c. 檢查換向閥氣路是否暢通;
C. check valve gas path is smooth;
2.泵動作突然加快,驅動活塞不到頭就換向:
2 pump action suddenly accelerate, driving the piston does not end on reversing:
a. 撞針漏氣。
A. striker leakage.
長期使用,尤其無油潤滑的情況下,可能會出面撞針前后腔串氣,致使撞針密封不好,換向閥工作不正常,泵頻率加快。
The long-term use, especially non oil lubricating condition, may step in to a cavity mixes up, resulting in the firing pin seal is not good, the reversing valve is not working properly, the pump speed.
當前位置: